Experimental Design of Vertical Distraction Osteogenesis Using Simple 3 Screws

使用简单 3 螺钉进行垂直牵张成骨的实验设计

阅读:6
作者:Zeyu Li, Dongbo Jiang, Yusheng Yao

Abstract

Distraction osteogenesis devices are complicated. To simplify these devices, we used 3 simple screws and 1 rubber band to realize the idea and analyzed histologic changes induced by mechanical forces. Ten female New Zealand white rabbits were studied. A left or right side of the mandible was randomly selected as the experimental side (ES). The unilateral mandible was distracted, and 2 fixation screws and 1 traction screw were implanted. When the traction screw was rotated downward, the opposite force made the osteotomy block move in opposite directions to increase the bone height. The control side (CS) was not processed. The results were assessed after 20 days of traction. Bone height in the ES increased by 5 mm. Toluidine blue staining showed that the number of osteoblasts per unit area on the ES was higher than that of the CS ( P <0.01). PerkinElmer showed that the expressions of proliferating cell nuclear antigen ( P =0.016) and collagen-I ( P =0.000) on the ES were higher than those on the CS. Transmission electron microscopy showed that the number of mitochondria, endoplasmic reticulum, and Golgi apparatus on the ES was significantly greater than the CS. The results confirmed that the 3 screws vertically increase the bone height. Mechanical force signals stimulate tissue activity and lead to significant cell proliferation and differentiation in the traction zone. Collagen-I may induce osteogenesis in the early stage of traction.

特别声明

1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。

2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。

3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。

4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。