Non-invasive left ventricular pressure-volume loops from cardiovascular magnetic resonance imaging and brachial blood pressure: validation using pressure catheter measurements

利用心血管磁共振成像和肱动脉血压进行无创左心室压力-容积环测量:采用压力导管测量进行验证

阅读:1

Abstract

AIMS: Left ventricular (LV) pressure-volume (PV) loops provide gold-standard physiological information but require invasive measurements of ventricular intracavity pressure, limiting clinical and research applications. A non-invasive method for the computation of PV loops from magnetic resonance imaging and brachial cuff blood pressure has recently been proposed. Here we evaluated the fidelity of the non-invasive PV algorithm against invasive LV pressures in humans. METHODS AND RESULTS: Four heart failure patients with EF < 35% and LV dyssynchrony underwent cardiovascular magnetic resonance (CMR) imaging and subsequent LV catheterization with sequential administration of two different intravenous metabolic substrate infusions (insulin/dextrose and lipid emulsion), producing eight datasets at different haemodynamic states. Pressure-volume loops were computed from CMR volumes combined with (i) a time-varying elastance function scaled to brachial blood pressure and temporally stretched to match volume data, or (ii) invasive pressures averaged from 19 to 30 sampled beats. Method comparison was conducted using linear regression and Bland-Altman analysis. Non-invasively derived PV loop parameters demonstrated high correlation and low bias when compared to invasive data for stroke work (R(2) = 0.96, P < 0.0001, bias 4.6%), potential energy (R(2) = 0.83, P = 0.001, bias 1.5%), end-systolic pressure-volume relationship (R(2) = 0.89, P = 0.0004, bias 5.8%), ventricular efficiency (R(2) = 0.98, P < 0.0001, bias 0.8%), arterial elastance (R(2) = 0.88, P = 0.0006, bias -8.0%), mean external power (R(2) = 0.92, P = 0.0002, bias 4.4%), and energy per ejected volume (R(2) = 0.89, P = 0.0001, bias 3.7%). Variations in estimated end-diastolic pressure did not significantly affect results (P > 0.05 for all). Intraobserver analysis after one year demonstrated 0.9-3.4% bias for LV volumetry and 0.2-5.4% for PV loop-derived parameters. CONCLUSION: Pressure-volume loops can be precisely and accurately computed from CMR imaging and brachial cuff blood pressure in humans.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。