Intravascular ultrasound-guided drug-coated balloon venoplasty for in-stent restenosis in pulmonary veins stenosis: a case report

血管内超声引导下药物涂层球囊静脉成形术治疗肺静脉支架内再狭窄:病例报告

阅读:1

Abstract

BACKGROUND: Pulmonary veins stenosis (PVS) after atrial fibrillation radiofrequency ablation is an uncommon complication. When it occurs, percutaneous treatment is the preferred approach. There is a lack of standardized procedures, and when stenting restenosis is relatively common. CASE SUMMARY: We present a young patient with recurrence of PVS after first percutaneous treatment. The recurrence of haemoptysis and dyspnoea after treatment in PVS allowed the diagnosis of significant stenosis again in our patient. In the Heart Team, we opted for a new percutaneous treatment, using intravascular ultrasound (IVUS) to optimize the final result. DISCUSSION: Nowadays, percutaneous approach is preferred and among percutaneous treatments for PVS, stenting has shown better results than balloon angioplasty (BA). Despite this, experience in in-stent restenosis is limited, and there is a lack of adequate and specific material for its approach. In this case, we present the possible role of the IVUS and the drug-coated BA in this entity.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。