Significant decrease in lipid core burden index following balloon dilation was associated with the leakage of cholesterol crystals in a patient: a case report

球囊扩张术后脂质核心负荷指数显著降低与患者胆固醇晶体渗漏相关:病例报告

阅读:1

Abstract

BACKGROUND: Near-infrared spectroscopy (NIRS) has been used for analysis the composition of the atherosclerotic plaque in coronary arteries. However, meaning of significant decrease in max lipid core burden index at 4 mm (max LCBI(4mm)) during percutaneous coronary intervention (PCI) is poorly understood. CASE SUMMARY: A 64-year-old male with unstable angina underwent coronary angiography, which demonstrated a hazy tight culprit lesion in the mid-right coronary artery. Pre-intervention NIRS-intravascular ultrasound (NIRS-IVUS) and chemogram showed plaque with high lipid burden at the culprit lesion. Then, we used a distal protection device before PCI because of high max LCBI(4mm) in the lesion. After pre-dilation with a scoring balloon, repeat NIRS-IVUS interrogation revealed an almost complete disappearance of the yellow signal and decrease in max LCBI(4mm) (from 537 to 44) significantly, suggesting decrease in the lipid content of the plaque. Finally, a drug-eluting stent deployment followed by inflation of a non-compliant balloon led to an excellent result. After PCI, we detected trapped large amounts of debris on retrieval of the filter. Pathological diagnosis confirmed that trapped material was lipid-rich plaque including cholesterol crystals. DISCUSSION: This is the first report directly demonstrated that significant decrease in max LCBI(4mm) at culprit lesion should be associated with the leakage of cholesterol crystals from lipid-rich plaque during PCI in the clinical patient.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。