Usefulness of Computed Tomography for Evaluating the Effects of Bronchial Thermoplasty in Japanese Patients with Severe Asthma

计算机断层扫描对评估日本重度哮喘患者支气管热成形术疗效的实用性

阅读:13
作者:Sumiko Abe, Mina Yasuda, Kazunori Tobino, Sonoko Harada, Hitoshi Sasano, Yuki Tanabe, Yuuki Sandhu, Tomohito Takeshige, Kei Matsuno, Tetsuhiko Asao, Takuto Sueyasu, Saori Nishizawa, Kohei Yoshimine, Yuki Ko, Yuki Yoshimatsu, Kosuke Tsuruno, Hiromi Ide, Haruhi Takagi, Jun Ito, Tetsutaro Nagaoka, Nori

Background

Bronchial thermoplasty (BT) improves clinical outcomes and quality of life for patients with severe asthma and has shown sustained reductions in airway narrowing and air trapping in previous CT studies. However, there is a lack of a comprehensive analysis, including CT evaluation, of clinical outcomes in Japanese patients who have undergone BT for severe asthma. This study aimed to evaluate the impact of BT in Japanese asthma patients, with a focus on the CT metric "WA at Pi10" to assess airway disease.

Conclusion

This study has limitations, including its single-arm observational design and the small sample size. However, BT led to a symptomatic improvement in patients with severe asthma. The validated "√WA at Pi10" metric on CT effectively evaluated the therapeutic response in Japanese asthma patients after BT.

Methods

Twelve patients with severe persistent asthma who underwent BT were assessed using ACQ6, AQLQ, pulmonary function tests, FeNO measurement, blood sampling, and chest CT before BT and one year after the third procedure for the upper lobes.

Results

The median age of the patient was 62.0 years, 7/12 (58.3%) were male, 4/12 (33.3%) used regular oral corticosteroids, and 8/12 (66.7%) received biologics. Median FEV1% was 73.6%, and median peripheral eosinophil count was 163.8/μL. After one year of BT, ACQ6 scores improved from 2.4 to 0.8 points (p = 0.007), and AQLQ scores improved from 4.3 to 5.8 points (p < 0.001). Significant improvements were also observed in asthma exacerbations, unscheduled visits due to exacerbations, FeNO, and √WA at Pi10 (p < 0.05). The baseline mucus score on the CT findings was negatively correlated with FEV1 (r = -0.688, p = 0.013) and with the maximum mid-expiratory flow rate (r = -0.631, p = 0.028), and positively correlated with the peripheral blood eosinophil count (r = -0.719, p = 0.008). Changes in √WA at Pi10 after one year were positively correlated with changes in the mucus score (r = 0.742, p = 0.007).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。