Perioperative complications associated with fluoroscopy C1 lateral mass screw fixation (Goel technique) versus computed tomography-guided navigation technique: A review of 202 cases from the German Spine Registry (DWG-Register)

透视引导下C1侧块螺钉固定术(Goel技术)与计算机断层扫描引导导航技术相关的围手术期并发症:德国脊柱注册中心(DWG注册中心)202例病例回顾

阅读:1

Abstract

BACKGROUND: Overview of the literature - Fractures of the C1 constitute 3%-13% of all cervical spine injuries in adults. Most isolated C1 fractures are stable and can be treated nonoperatively with external immobilization. Traditional surgical options for C1 fracture treatment are occiput-to-C2 fusion or C1 with lateral mass screws (LMSs). Purpose - The aim is to assess the management and perioperative complications of C1 fractures undergoing LMS fusion between fluoroscopy and computed tomography (CT)-guided navigation. METHODS: This was a retrospective multicenter study of data from the DWG-Register of patients who underwent operative treatment for C1 traumatic fracture with LMSs from January 2017 to September 2022. Inclusion criteria - traumatic injury and age > 18 years old. RESULTS: In total, 202 patients with traumatic C1 fracture requiring spinal surgery were identified in the registry; n = 175 (Group 1) were treated conventionally without CT-guided navigation and n = 27 were treated with CT-guided navigation (Group 2). C1-LMS was principally performed by spine surgeons n = 90 (53.4%) and n = 72 (18.5%) by neurosurgeons in both the groups. Intraoperative adverse events were as follows: dural tear in group 1 n = 0 and in group 2 n = 1, vascular injury, with one case in group 1 and no cases in group 2. General complications were: cardiovasculars in group 1 n = 6 (3.4%) and Group 2 n = 4 (14.8%) (P = 0.03), pulmonary complications in group1 n = 2 (1.1%) and n = 9 in group 2 (33.3%) (P < 0.001), stroke n = 1 (0.57%) in group1 and n = 4 in group 2 (14.8%) (P < 0.001), gastrointestinal bleeding n = 1 (0.57%) in group1 and no cases in group 2, renal insufficiency n = 2 (1.1%) in group 1 and n = 3 (11.1%) in group 2 (P = 0.01). One death was recorded in group 2 (3.7%). CONCLUSION: This series of 404 screws placed in 202 patients over 5 years who underwent two types of C1 fracture fixation had a considerably lower incidence of screw malposition and vertebral artery injury than has previously been reported in the literature. C1 screws can be safely placed with a low risk of vertebral artery and neurologic injury with and without CT-guided navigation support.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。