Sorting by interfacial tension (SIFT): Label-free enzyme sorting using droplet microfluidics

按界面张力分类 (SIFT):使用液滴微流体进行无标记酶分类

阅读:7
作者:Daniel G Horvath, Samuel Braza, Trevor Moore, Ching W Pan, Lailai Zhu, On Shun Pak, Paul Abbyad

Abstract

Droplet microfluidics has the ability to greatly increase the throughput of screening and sorting of enzymes by carrying reagents in picoliter droplets flowing in inert oils. It was found with the use of a specific surfactant, the interfacial tension of droplets can be very sensitive to droplet pH. This enables the sorting of droplets of different pH when confined droplets encounter a microfabricated trench. The device can be extended to sort enzymes, as a large number of enzymatic reactions lead to the production of an acidic or basic product and a concurrent change in solution pH. The progress of an enzymatic reaction is tracked from the position of a flowing train of droplets. We demonstrate the sorting of esterase isoenzymes based on their enzymatic activity. This label-free technology, that we dub droplet sorting by interfacial tension (SIFT), requires no active components and would have applications for enzyme sorting in high-throughput applications that include enzyme screening and directed evolution of enzymes.