Comparative analysis of air permeability between UHPC and epoxy-coated normal concrete for hyperloop tube structures

超高性能混凝土与环氧涂层普通混凝土在超级高铁管道结构中的透气性对比分析

阅读:1

Abstract

This study evaluates the air permeability of epoxy-coated normal concrete and ultra-high performance concrete (UHPC) for use in Hyperloop tube structures, where maintaining ultra-low air permeability is crucial to preserving the vacuum environment. While UHPC is recognized for its exceptionally low permeability due to its dense microstructure, this research explores epoxy-coated conventional concrete as a cost-effective alternative. Using a vacuum-based permeability test simulating Hyperloop's near-vacuum conditions, the study found that epoxy-coated concrete significantly reduced air permeability compared to uncoated concrete, with specimens coated on both sides approaching near-zero permeability. Although UHPC exhibited superior performance, the epoxy-coated concrete demonstrated air-tightness and was suitable for Hyperloop applications, offering a viable and economical alternative. These findings provide important insights for material selection, suggesting that epoxy-coated conventional concrete can effectively meet the stringent requirements for Hyperloop tube construction while balancing performance with cost-efficiency.