Direct Electrochemical Sensing of Hydrogen Sulfide without Sulfur Poisoning

直接电化学传感硫化氢,避免硫中毒

阅读:1

Abstract

An electrochemical method capable of direct, real-time detection of hydrogen sulfide was developed using triple pulse amperometry (TPA) to mitigate sulfur poisoning and its related passivation of the working electrode surface. Through repeated cycles of discrete potential pulses, the electrooxidation of surface-adsorbed elemental sulfur to water-soluble sulfate ions was exploited to regenerate the glassy carbon electrode surface and maintain consistent sensor performance. Amperometric measurements and X-ray photoelectron spectroscopy surface analysis demonstrated that the TPA sensors provided enhanced analytical performance via decreased sulfur accumulation relative to low-potential (≤+0.7 V) constant potential amperometry. Sensors operated under optimized TPA parameters retained high sensitivity (57.4 ± 13.0 nA/μM), a wide linear dynamic range (150 nM-15 μM), fast response times (<10 s), and a submicromolar detection limit (<100 nM) upon consecutive calibration cycles. The sensitivity and response time achieved were comparable to or better than current electrochemical sensors. Moreover, the simplicity of the method eliminates the need for external redox mediators or semipermeable membranes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。