Persistent bronchography in a newborn with esophageal atresia

新生儿食管闭锁持续性支气管造影

阅读:2

Abstract

Esophageal atresia (EA) with tracheoesophageal fistula occurs in about 1:2,500 births. We report a case of persistent bronchography in a newborn with EA and distal tracheoesophageal fistula. A large amount of barium sulfate was injected for mistake by a tube directly in the right bronchus to evaluate the patency of the esophagus. The infant showed signs of respiratory distress; he was intubated and transported at children's Hospital Santobono Pausilipon. Here, it was performed a chest X-ray that confirmed the opacification of the right bronchial tree, and it was suspected an EA type 3b. The literature recommends that: evaluation of the patency of the esophagus, with an iodinate contrast medium, should be done in a pediatric specialized center for high risk of lung aspiration.