Background
Steps have been taken by pharmaceutical companies to obtain marketing authorisation of PSMA ligands in the European Union. Since December 2022, Locametz® (PSMA-11, gozetotide) is licensed as kit for manual radiolabelling with gallium-68 and commercially available since mid-2023. The Summary of Product Characteristic (SmPC) describes manual radiolabelling with a maximum activity after radiolabelling of 1369 MBq. We aimed for radiolabelling with a higher activity to increase production efficiency, and thus, automated radiolabelling is strongly preferred over manual radiolabelling to reduce radiation exposure to personnel. The
Conclusion
Automated radiolabelling of [68Ga]Ga-PSMA-11 using the Locametz® kit with higher gallium-68 activity than specified in the SmPC results in a product that is in compliance with the Ph. Eur. monograph and has a shelf-life of 6 h at room temperature. Radiolabelling with two generators proved possible and resulted in a product with similar quality but with much higher efficiency.
Results
Automated radiolabelling of [68Ga]Ga-PSMA-11 using the Locametz® kit provided a product which complies to the Ph. Eur., had a shelf-life of 6 h at room temperature, and theoretically reduced radiation exposure 5.7 times. Radiolabelling with one and two generator(s) resulted in a radiochemical yield of 91-102% and 96-101% after preparation, respectively. The radiochemical purity ranged from 98.0 to 99.6% for radiolabelling with one generator and ranged from 98.4 to 99.3% for radiolabelling with two generators with similar stability. The activity of the final product was much higher when using two generators, 1961-2035 MBq compared to 740-1260 MBq, which leads to ~ 1.5 times more patient syringes available per preparation.