Successful flow diversion treatment of ruptured infectious middle cerebral artery aneurysms with the use of Pipeline Flex with Shield technology

采用 Pipeline Flex with Shield 技术成功治疗破裂性感染性大脑中动脉瘤。

阅读:1

Abstract

BACKGROUND: Rupture of infectious intracranial aneurysms (IIAs) is associated with a high likelihood of mortality. Endovascular treatment of IIAs via parent artery sacrifice offers good efficacy and outcomes; however, depending on the lesion's location, neurologic deficit may result. CASE DESCRIPTION: We describe a pediatric patient with ruptured IIAs off the left middle cerebral artery (MCA) treated with coil embolization and endovascular flow diversion using the Pipeline Flex Embolization Device (PED) with Shield technology. We chose to place a flow diverter because 1) there was a second, more distal IIA not amenable to direct coil embolization, 2) there was significant potential for aneurysm regrowth and need for retreatment, and 3) we believed the diseased parent MCA needed to be reconstructed. CONCLUSIONS: In the setting of previous hemicraniectomy, PED-Shield gave us the option to discontinue dual antiplatelet therapy should the patient require further neurosurgical intervention. Our case supports a role for PED-Shield to address ruptured pseudoaneurysms.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。