Efficacy of high-resolution cone-beam CT in the evaluation of perforators in vertebral artery dissection

高分辨率锥形束CT在椎动脉夹层穿支血管评估中的疗效

阅读:1

Abstract

Introduction A major complication of internal coil trapping for vertebral artery dissection (VAD) is medullary infarction associated with perforator occlusion. Currently, higher spatial resolution imaging can be obtained with high-resolution cone-beam computed tomography (VASO CT), and the efficacy of perforator visualization adjacent to VAD was examined. Methods Eight patients who underwent internal coil trapping or stent-supported coil embolization underwent VASO CT to evaluate perforators around VAD. Visualization of perforators was compared with conventional digital subtraction angiography (DSA) and three-dimensional rotational angiography (3D-RA). Postoperative MRI was performed in all patients to investigate ischemic complications. The relationship between the perforators and the infarction was analyzed. Results Perforator visualization was much clearer on VASO CT than on 2D DSA or 3D-RA. It was sharp enough to identify each perforating artery. Medullary infarctions were detected in two cases. In these two cases, each ischemic lesion corresponded to the territory of a perforator that was well visualized on VASO CT. The axial view with adjoining tissue structures on VASO CT was useful to detect the territories of perforators. Conclusions VASO CT is an efficient modality for the detection and identification of perforators in the vicinity of VAD. It provides accurate anatomical information about the vertebrobasilar system that is useful for the treatment of unruptured VAD.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。