Periareolar endoscopic minimally invasive cardiac surgery: postoperative scar assessment analysis

乳晕周围内镜微创心脏手术:术后瘢痕评估分析

阅读:1

Abstract

OBJECTIVES: The standard approach for minimally invasive cardiac surgery (MICS) for repair of the atrioventricular valves is a right lateral minithoracotomy. In this study, we report our experience with a periareolar endoscopic approach, which aims at an optimal cosmetic outcome while preserving optimal clinical outcomes. METHODS: All patients underwent periareolar endoscopic MICS using high-definition three-dimensional endoscopic visualization without additional rib-spreading. Patients presented with degenerative and/or functional mitral regurgitation. Patients undergoing concomitant tricuspid valve surgery, cryo-ablation, patent foramen ovale closure, left atrial appendage occlusion and/or left atrial myxoma extirpation were included. This descriptive article analysed the aesthetic and functional outcome of the periareolar scar using 5 most common and clinimetrically sound scar assessment scales. For statistical analysis of the scar assessment grading scales, box and whisker plots were calculated depicting median, interquartile range and high and low range data points. RESULTS: Median scar assessment scale scores for n = 100 male patients (response rate 100/109; 91.7%) were 2 [1, 4], 7.5 [6, 9], 11 [8, 14], 3 [2, 3] and 10 [9, 11] for the Vancouver scar scale, Manchester scar scale, patient scar assessment scale, Stony brook scar evaluation scale and Dermatology Quality of Life Index scale, respectively. Ninety-seven patients received mitral valve repair, 7 mitral valve replacement, whereas 5 had left atrial myxoma extirpation. Concomitant tricuspid annuloplasty, cryo-ablation, left atrial appendage occlusion and patent foramen ovale closure surgery were performed in 12, 29, 5 and 8 patients, respectively. Median procedure, cardiopulmonary bypass and cross-clamp times were 169.5 [154.3, 189.3], 111.5 [97, 127], and 68.5 [58.8, 81] min, respectively. CONCLUSIONS: Periareolar endoscopic MICS is safe and cosmetically appealing. It is feasible and allows for complex mitral valve repair, mitral valve replacement and concomitant surgery. Data from 5 scar assessment scales suggest that this technique delivers patient-satisfying results regarding functional and cosmetic outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。