An Unexpected Complication Resulting from Radiofrequency Ablation for Treating Facet Joint Syndrome: A Case Report

射频消融治疗小关节综合征引起的意外并发症:病例报告

阅读:2

Abstract

Lumbar facet joints have been identified as a potential source of chronic low back pain (LBP) in 15% to 45% of patients, with the prevalence of such pain varying based on specific populations and settings examined. Lumbar facet joint interventions are useful in the diagnosis as well as the therapeutic management of chronic LBP. Radiofrequency ablation (RFA) of medial branch nerves is recognized as a safe and effective therapy for chronic facet joint pain in the lumbosacral spine, and its efficacy has already been established. The use of RFA is currently widespread in the management of spinal pain, but it is noteworthy that there have been works in the literature reporting complications, albeit at a very low frequency. We present a case of third-degree skin burns following radiofrequency ablation (RFA) for the management of facet joint syndrome. Postoperatively, the patient's skin encircling the needle displayed a pallor and exhibited deterioration in conjunction with the anatomical anomaly. The affected area required approximately 5 months to heal completely. During RFA, heat can induce burns not only at the point of contact with the RF electrode but also along the length of the needle. Vigilant attention is necessary to ensure patient safety and to address any potential complications that may arise during the procedure, including the possibility of minor technical errors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。