Flow-S: A Field-Deployable Device with Minimal Hands-On Effort to Concentrate and Quantify Schistosoma Circulating Anodic Antigen (CAA) from Large Urine Volumes

Flow-S:一种现场可部署的设备,只需极少的手动操作即可从大量尿液中浓缩和量化血吸虫循环阳极抗原 (CAA)

阅读:9
作者:Daniëlle de Jong, Cody Carrell, Jane K Maganga, Loyce Mhango, Peter S Shigella, Maddy Gill, Ryan Shogren, Brianna Mullins, Jay W Warrick, John M Changalucha, Govert J van Dam, Khanh Pham, Jennifer A Downs, Paul L A M Corstjens

Abstract

A laboratory-based lateral flow (LF) test that utilizes up-converting reporter particles (UCP) for ultrasensitive quantification of Schistosoma circulating anodic antigen (CAA) in urine is a well-accepted test to identify active infection. However, this UCP-LF CAA test requires sample pre-treatment steps not compatible with field applications. Flow, a new low-cost disposable, allows integration of large-volume pre-concentration of urine analytes and LF detection into a single field-deployable device. We assessed a prototype Flow-Schistosoma (Flow-S) device with an integrated UCP-LF CAA test strip, omitting all laboratory-based steps, to enable diagnosis of active Schistosoma infection in the field using urine. Flow-S is designed for large-volume (5-20 mL) urine, applying passive paper-based filtration and antibody-based CAA concentration. Samples tested for schistosome infection were collected from women of reproductive age living in a Tanzania region where S. haematobium infection is endemic. Fifteen negative and fifteen positive urine samples, selected based on CAA levels quantified in paired serum, were analyzed with the prototype Flow-S. The current Flow-S prototype, with an analytical lower detection limit of 1 pg CAA/mL, produced results correlated with the laboratory-based UCP-LF CAA test. Urine precipitates occurred in frozen banked samples and affected accurate quantification; however, this should not occur in fresh urine. Based on the findings of this study, Flow-S appears suitable to replace the urine pre-treatment required for the laboratory-based UCP-LF CAA test, thus allowing true field-based applications with fresh urine samples. The urine precipitates observed with frozen samples, though less important given the goal of testing fresh urines, warrant additional investigation to evaluate methods for mitigation. Flow-S devices permit testing of pooled urine samples with applications for population stratified testing. A field test with fresh urine samples, a further optimized Flow-S device, and larger statistical power has been scheduled.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。