Enhancing Lesion Detection in Inflammatory Myelopathies: A Deep Learning-Reconstructed Double Inversion Recovery MRI Approach

增强炎性脊髓病病灶检测:一种基于深度学习重建的双反转恢复磁共振成像方法

阅读:3

Abstract

BACKGROUND AND PURPOSE: The imaging of inflammatory myelopathies has advanced significantly across time, with MRI techniques playing a pivotal role in enhancing lesion detection. However, the impact of deep learning (DL)-based reconstruction on 3D double inversion recovery (DIR) imaging for inflammatory myelopathies remains unassessed. This study aimed to compare the acquisition time, image quality, diagnostic confidence, and lesion detection rates among sagittal T2WI, standard DIR, and DL-reconstructed DIR in patients with inflammatory myelopathies. MATERIALS AND METHODS: In this observational study, patients diagnosed with inflammatory myelopathies were recruited between June 2023 and March 2024. Each patient underwent sagittal conventional TSE sequences and standard 3D DIR (T2WI and standard 3D DIR were used as references for comparison), followed by an undersampled accelerated double inversion recovery deep learning (DIR(DL)) examination. Three neuroradiologists evaluated the images using a 4-point Likert scale (from 1 to 4) for overall image quality, perceived SNR, sharpness, artifacts, and diagnostic confidence. The acquisition times and lesion detection rates were also compared among the acquisition protocols. RESULTS: A total of 149 participants were evaluated (mean age, 40.6 [SD, 16.8] years; 71 women). The median acquisition time for DIR(DL) was significantly lower than for standard DIR (298 seconds [interquartile range, 288-301 seconds] versus 151 seconds [interquartile range, 148-155 seconds]; P < .001), showing a 49% time reduction. DIR(DL) images scored higher in overall quality, perceived SNR, and artifact noise reduction (all P < .001). There were no significant differences in sharpness (P = .07) or diagnostic confidence (P = .06) between the standard DIR and DIR(DL) protocols. Additionally, DIR(DL) detected 37% more lesions compared with T2WI (300 versus 219; P < .001). CONCLUSIONS: DIR(DL) significantly reduces acquisition time and improves image quality compared with standard DIR, without compromising diagnostic confidence. Additionally, DIR(DL) enhances lesion detection in patients with inflammatory myelopathies, making it a valuable tool in clinical practice. These findings underscore the potential for incorporating DIR(DL) into future imaging guidelines.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。