Effects of Biomechanical Testing Using a Synthetic Ligament Fabricated from Polyhydroxyalkanoate Biopolyesters for Lateral Ulnar Collateral Ligament Reconstruction in Cadaver

利用聚羟基烷酸酯生物聚酯制成的合成韧带进行尸体外侧尺侧副韧带重建的生物力学测试效果

阅读:2

Abstract

An injury to the elbow's lateral ulnar collateral ligament (LUCL) is an orthopedic emergency that can impair joint stability and functional biomechanics throughout the upper extremity. The development and application of synthetic ligament substitutes, particularly short-chain-length and medium-chain-length polyhydroxyalkanoate (SCL-PHA and MCL-PHA) co-polymers, represent a promising innovation for lateral elbow stabilization. This experimental cadaveric study aimed to (1) compare biomechanical parameters of torque and angular rotation among control, damage, repair, and reconstruction groups and (2) compare stress and strain responses across the same groups. Twenty-four cadaveric elbows were allocated among six experimental conditions. The control group consisted of intact elbows (n = 4), while the damage group (n = 4) involved transection of the anterior capsule and extensor carpi radialis brevis (ECRB) to simulate ligament injury. The repair group (n = 4) underwent anterior capsular suturing. The reconstruction group (n = 12) was divided into three subgroups: palmaris longus (PL) autograft alone, PL with SCL-PHA co-polymer augmentation, and PL with MCL-PHA augmentation. Biomechanical testing measured maximum torque, angular displacement, shear stress, and strain, with statistical analysis conducted using descriptive statistics, one-way ANOVA, and post hoc multiple comparisons. The results demonstrated that maximum torque (F = 24.930, p < 0.001) and maximum shear stress (F = 8.130, p < 0.001) significantly differed among groups. The control group exhibited the highest mechanical performance (30.700 ± 9.368 Nm and 0.880 ± 0.216 MPa), whereas the damage group showed the lowest values (10.300 ± 2.904 Nm and 0.210 ± 0.073 MPa). The reconstruction group using palmaris longus with SCL-PHA co-polymer reinforcement (RC-PLSCL) demonstrated torque (29.550 ± 7.656 Nm) and shear stress (0.610 ± 0.206 MPa) comparable to those of the control group (p > 0.05), indicating near-physiological mechanical behavior. These findings suggest that SCL-PHA co-polymer augmentation offers superior biomechanical restoration relative to standard repair and other reconstruction strategies, highlighting its potential as an advanced biomaterial for ligament reconstruction in LUCL injuries.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。