Radiopacity evaluation of contemporary resin composites by digitization of images

通过图像数字化评估现代树脂复合材料的放射阻射性

阅读:1

Abstract

OBJECTIVE: The aim of this study was to evaluate the radiopacity of different composite resins and compare the values to those of human enamel and dentine. MATERIALS AND METHODS: Five specimens of each material with thicknesses of 2 mm were prepared and radiographed alongside aluminum step wedge and human enamel and dentin. Three occlusal radiographs for each material were taken and digitized using a desktop scanner. Mean gray values of the test materials were measured using Image J software. Then a conversion was performed according to establish the radiopacity of the test materials, in millimeters of equivalent Al. Data were analyzed using one-way analysis of variance and Duncan multiple range tests (P < 0.05). RESULTS: The radiopacity values varied among the restorative materials (P < 0.05). The radiopacity values of the materials tested were, in decreasing order: Enamel Plus HRI > Z250 > Filtek Ultimate ≥ Z550 > Nexcomp ≥ Nanoceram Bright > enamel ≥ Estelite Sigma Quick > Clearfil Majesty Esthetic ≥ Reflexions XLS ≥ Aelite LS Posterior ≥ dentin ≥ 2 mm Al. CONCLUSION: All resin composite materials investigated in this study presented different radiopacity values. However, all materials had radiopacity values greater than dentin and had sufficient radiopacity to meet International Organization for Standardization 4049 standard.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。