Evaluation of the Water Sorption and Solubility Behavior of Different Polymeric Luting Materials

不同聚合物粘合剂吸水和溶解性能的评价

阅读:1

Abstract

Objective: The study evaluated the water sorption (WSP) and water solubility (WSL) characteristics of different luting agents over a 180-day water storage period. Materials and Methods: Nine luting materials, i.e., conventional resin cement: Panavia F (PF), Rely X ARC (RA), self-adhesive resin cement: Rely X Unicem (RU), Breez (BZ), Maxcem Elite (MX), BisCem (BC) and resin-modified glass ionomer cement: FujiCem (FC), FujiPlus (FP) Rely X luting plus (RL) were assessed and fifty-two-disc specimens of each material were fabricated. All specimens were desiccated until a constant weight (W0) was reached. Thirteen specimens for each luting material were then randomly assigned to one of the four water immersion periods (7, 30, 90, and 180 days). After each period, the specimens were removed from the water and weighed to get W1. The samples were again desiccated for a second time and W(2) was measured. Both WSP and WSL were determined by the following equations: WSP (%) = (W(1) - W(2)) × 100/W(0) and WSL (%) = (W(0) - W(2)) × 100/W(0). Assessments were performed following ISO standards. ANOVA was used to assess the effect of luting agent and time period on water sorption and solubility. Pair-wise comparisons were adjusted using Tukey's multiple comparison procedure. A significance level of 0.05 was used for all statistical tests. Results: The highest mean WSP and WSL (WSP/WSL) were demonstrated by resin-modified glass-ionomers (RL 18.32/3.25, FC 17.08/4.83, and FP 14.14/1.99), while resin luting agents showed lower WSP and WSL results (PF 1.6/0.67 and RA 1.76/0.46), respectively. The self-adhesive agents exhibited a wide range of WSP and WSL values (RU 1.86/0.13, BZ 4.66/0.93, and MX 3.68/1.11). Self-adhesive cement showed lower WSP and WSL compared with the resin-modified glass-ionomers (p < 0.05). All the materials reached equilibrium after 90-days. Conclusions: Resin-based luting materials have the lowest sorption and solubility. Rely X Unicem self-adhesive luting materials were comparable to resin luting materials for WSL and WSP. Resin-modified glass-ionomer showed the highest water sorption and solubility compared with both resin and self-adhesive materials.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。