X-Ray Attenuation Properties of Additive Manufacturing and 3D Printing Materials for Mimicking Tissues in Radiographic Phantoms Measured by CT from 70 to 140 kV: 2025 Update

利用 70 至 140 kV CT 测量增材制造和 3D 打印材料在放射线模型中模拟组织的 X 射线衰减特性:2025 年更新

阅读:1

Abstract

BACKGROUND: Phantoms are essential in medical imaging, providing reproducible and quantitative means for system and protocol evaluation, image quality assessment, and dosimetry without patient exposure. Additive manufacturing enables rapid, accurate fabrication of phantoms ranging from simple geometries to complex anthropomorphic models. Ongoing developments in 3D printing technologies and polymer formulations have enhanced mechanical properties and printability, but also affect X-ray attenuation behaviour, necessitating an update with current materials to facilitate the choice of appropriate materials mimicking body tissues in radiographic phantoms. METHODS: Attenuation properties of 27 photopolymer resins and 22 thermoplastic filaments (based on PLA, ABS, HIPS, PETG/PCTG, and PVB) were quantified using a clinical CT scanner at 70-140 kV to establish reference data for material selection. RESULTS: At 120 kV, resins exhibited attenuation values between 124 and 384 Hounsfield Units (HU), and filaments ranged from -69 to 308 HU (PLA-based filaments: 160 to 241 HU, ABS: -32 to 43 HU, PETG/PCTG: 151 to 308 HU, and HIPS: -69 to -22 HU). Energy dependence of HU values is presented from 70 to 140 kV tube potential. Compared to the 2021 study, a wider selection of X-ray opacities is available. Regarding SLA/DLP printing, resins with higher attenuation were identified, and flexible resins that had provided a choice of low attenuation printing materials in the range of 60 to 90 HU at 120 kV tended to replicate attenuation properties closer to rigid photopolymers; i.e., HU values were slightly higher. In FDM filaments, a wide variation in different PLA-, ABS-, and HIPS-based filaments is found. In copolymers from the PET/PCTG/PETG family, very inhomogeneous X-ray attenuations are still found, as anticipated. CONCLUSIONS: The range of X-ray attenuation observed demonstrates that commercially available 3D printing materials can replicate clinically relevant tissues and tissue-equivalent contrasts. Furthermore, the available range of attenuations has increased, as has the finer gradation of these materials. These findings support the design of patient- and task-specific imaging phantoms for optimization of acquisition protocols, image quality evaluation, and radiation dose studies, as well as facilitate the selection of appropriate phantom materials.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。