AIM: To assess the effect of multiple reuse of implant analogs of three different materials (SS, Ti, Al) on the changes in the distance between internal threads of implant analog by using two die materials at different time intervals (0, 3(rd), 6(th), 9(th), and 12(th)). SETTINGS AND DESIGN: An in vitro study. MATERIALS AND METHODOLOGY: Three commonly used implant analog materials (stainless steel, titanium, and aluminum) and two Type- IV die stone materials (Kalrock and Zhermack Elite) were used to make the samples. A total of sixty implant analogs (20 each), sixty corresponding abutments (20 each) and 720 screws (240 each) were taken, which includes stainless steel, titanium, and aluminum manufactured by Adin, Genesis, and Equinox/Myriad plus, respectively. In addition, silicone (light body consistency) was used to make an impression for the internal thread of implant analogs. The obtained samples were tested for changes in the internal threads of implant analogs while reusing the implant analogs at the interval of times (0, 3(rd), 6(th), 9(th), and 12(th)) using a stereomicroscope at ×50. Here, the measured values at "0" interval were considered the control group. STATISTICAL ANALYSIS USED: The values obtained were statistically analyzed using One way ANOVA, independent t test, and dependent t test for multiple comparisons. RESULTS: Based on the results obtained, the overall comparison of the mean distance between threads 1-2, 3-4, and 5-6 on the replica of internal threads of the stainless steel, titanium, and aluminum implant analog materials at 1-2 has more decrease in distance from 0 to 12(th) intervals, at 3-4 has less amount of decrease in distance than thread distance at 1-2 from 0 to 12(th) intervals, and at 5-6 has very less decrease in distance than thread distance at 1-2 and 3-4 from 0 to 12(th) intervals. On order the mean distance reduction between threads is more at 1-2, followed to that less reduction at 3-4 and very less reduction at 5-6. This infers that the amount of increase in the distance between the internal threads of implant analog at 1-2 has more followed by 3-4 and 5-6, respectively. CONCLUSION: From the study, the following inferences are drawn: That the aluminum implant analog internal threads have more amount of increase in the distance between threads followed by stainless steel and titanium. Hence, among the three materials, titanium implant analogs were most efficient for reuse.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。