Microhardness of glass carbomer and high-viscous glass Ionomer cement in different thickness and thermo-light curing durations after thermocycling aging

不同厚度和热光固化时间后,玻璃碳素和高粘度玻璃离子水门汀经热循环老化后的显微硬度

阅读:1

Abstract

BACKGROUND: The objective of our study was to compare the upper and lower surface microhardness and surface changes of Glass Carbomer Cement (GCP) and EQUIA Forte (EF) in different thickness after thermo-light curing durations and aging. METHODS: A total of 504 samples (5 mm-diameter) were prepared by using GCP-252 (GCP Dental, and Vianen, Netherlands) and EF-252 (EQUIA Forte, GC, Tokyo, Japan). Three different thickness samples (2, 4, and 6 mm) were prepared with 84 samples in each subgroup. The samples were prepared by three curing procedures (Non-exposed, 60s, 90s). Their varnishes were applied to the upper surfaces of half of each subgroup (n = 7). The upper microhardness measurements were evaluated before and after aging. To compare the effect of different thicknesses, the bottom surfaces of the samples were evaluated before aging in terms of microhardness measurements. Also, the upper surfaces were analyzed in the SEM before and after aging. RESULTS: The upper surface values of all the samples were higher than the bottom values (p < 0.05). There were no significant differences between the varnished and non-varnished samples in both materials (p > 0.05). Although this increase was not significant in some groups, temperature variations increased the surface microhardness values of both materials except for the non-exposed-varnished EF samples. The highest microhardnesses values were recorded in the non-exposed-varnished EF (125.6 ± 6.79) and unvarnished GCP (88.1 ± 7.59) samples which were thermo-light cured for 90 s before aging. The bottom hardness values were affected by thickness variations in both GCP and EF materials (p < 0.05). The sample deformations and microcracks after aging were greater than before in all the materials. Thermo-light curing in 90 s to the samples reduced the cracks in both the materials before and after aging. CONCLUSIONS: Thermal aging adversely affected the microhardness of the materials, which is important for clinical success. The thermo-light curing process improved the microhardness of the GCP group without varnish application. Varnish application increased the microhardness of the EF group without applying thermo-light curing. The microhardness of the bottom surfaces decreased with increasing thickness. The thermo-light curing did not increase the bottom surface microhardness of all the samples.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。