Reliability of mobility measures in older medical patients with cognitive impairment

老年认知障碍患者行动能力评估的可靠性

阅读:1

Abstract

BACKGROUND: Mobility is a key indicator of physical functioning in older people, but there is limited evidence of the reliability of mobility measures in older people with cognitive impairment. This study aimed to examine the test-retest reliability and measurement error of common measurement instruments of mobility and physical functioning in older patients with dementia, delirium or other cognitive impairment. METHODS: A cross-sectional study was performed in a geriatric hospital. Older acute medical patients with cognitive impairment, indicated by a Mini-Mental State Examination (MMSE) score of ≤24 points, were assessed twice within 1 day by a trained physiotherapist. The following instruments were applied: de Morton Mobility Index, Hierarchical Assessment of Balance and Mobility, Performance-Oriented Mobility Assessment, Short Physical Performance Battery, 4-m gait speed, 5-times chair rise test, 2-min walk test, timed up and go test, Barthel Index mobility subscale and Functional Ambulation Categories. As appropriate, the intraclass correlation coefficient (ICC), Cohen's kappa, standard error of measurement, limits of agreement and minimal detectable change (MDC) values were estimated. RESULTS: Sixty-five older acute medical patients with cognitive impairment participated in the study (mean age: 82 ± 7 years; mean MMSE: 20 ± 4, range: 10 to 24 points). Some participants were physically or cognitively unable to perform the gait speed (46%), 2-min walk (46%), timed up and go (51%) and chair rise (75%) tests. ICC and kappa values were above 0.9 in all instruments except for the gait speed (ICC = 0.86) and chair rise (ICC = 0.72) measures. Measurement error is reported for each instrument. The absolute limits of agreement ranged from 11% (de Morton Mobility Index and Hierarchical Assessment of Balance and Mobility) to 35% (chair rise test). CONCLUSIONS: The test-retest reliability is sufficient (> 0.7) for group-comparisons in all examined instruments. Most mobility measurements have limited use for individual monitoring of mobility over time in older hospital patients with cognitive impairment because of the large measurement error (> 20% of scale width), even though relative reliability estimations seem sufficient (> 0.9) for this purpose. TRIAL REGISTRATION: German Clinical Trials Register ( DRKS00005591 ). Registered 2 February 2015.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。