Aim

To assess the effect of PHT on the levels of detectable anti-FVIII IgG4 .

Conclusion

The optimal temperature for PHT in the FVIII NBA is 56°C. Higher temperatures may lead to loss of inhibitory antibodies.

Methods

Nijmegen-Bethesda assay-positive specimens were incubated at 56, 58 or 60°C for 90 minutes, and anti-FVIII IgG4 was measured by fluorescence immunoassay (FLI) at 30-minute intervals. The effects of PHT on the ability of recombinant FVIII (rFVIII) to inhibit detection of patient antibodies by FLI was also examined to assess the stability of rFVIII under the various PHT conditions tested.

Results

Levels of anti-FVIII IgG4 showed little change following incubations at 56°C (mean 101% of original value at 30 minutes and 100% at 60 minutes) but decreased upon exposure to 58°C (mean 85% at 30 minutes and 66% at 60 minutes). In addition, heating to 56°C effectively decreased the ability of rFVIII to block antibody binding compared to unheated rFVIII.