Evaluation of the Phoenix 100 ID/AST system and NID panel for identification of Enterobacteriaceae, Vibrionaceae, and commonly isolated nonenteric gram-negative bacilli

评估 Phoenix 100 ID/AST 系统和 NID 检测板在鉴定肠杆菌科、弧菌科和常见分离的非肠道革兰氏阴性杆菌方面的性能

阅读:1

Abstract

The Phoenix 100 ID/AST system (Becton Dickinson Co., Sparks, Md.) is an automated system for the identification and antimicrobial susceptibility testing of bacterial isolates. This system with its negative identification (NID) panel was evaluated for its accuracy in the identification of 507 isolates of the family Enterobacteriaceae, 57 other nonenteric gram-negative isolates that are commonly isolated in clinical microbiology laboratories, and 138 isolates of the family Vibrionaceae. All of the isolates had been characterized by using approximately 48 conventional tube biochemicals. Of the 507 isolates of the Enterobacteriaceae, 456 (89.9%) were correctly identified to the genus and species levels. The five isolates of Proteus penneri required an off-line indole test, as suggested by the system to differentiate them from Proteus vulgaris. The identifications of 20 (3.9%) isolates were correct to the genus level but incorrect at the species level. Two (0.4%) isolates were reported as "no identification." Misidentifications to the genus and species levels occurred for 29 (5.7%) isolates of the Enterobacteriaceae. These incorrect identifications were spread over 14 different genera. The most common error was the misidentification of Salmonella species. The shortest time for a correct identification was 2 h 8 min. The longest time was 12 h 27 min, for the identification of a Serratia marcescens isolate. Of the 57 isolates of nonenteric gram-negative bacilli (Acinetobacter, Aeromonas, Burkholderia, Plesiomonas, Pseudomonas, and Stenotrophomonas spp.), 48 (84.2%) were correctly identified to the genus and species levels and 7 (12.3%) were correctly identified to the genus level but not to the species level. The average time for a correct identification was 5 h 11 min. Of the Vibrionaceae spp., 123 (89.1%) were correctly identified at the end of the initial incubation period, which averaged 4 h. Based on the findings of this study, the Phoenix 100 ID/AST system NID panel falls short of being an acceptable new method for the identification of the Enterobacteriaceae, Vibrionaceae, and gram-negative nonenteric isolates that are commonly encountered in many hospital microbiology laboratories.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。