Repeatability of measurements and sources of variability in tests of cardiovascular autonomic function

心血管自主神经功能测试中测量结果的重复性和变异来源

阅读:1

Abstract

OBJECTIVE: To determine the repeatability and sources of variability of clinical tests of cardiovascular autonomic function. DESIGN: The commonly used electrocardiographic related tests of autonomic function were studied. Two repeat measurements of all tests were made on all subjects on four separate days over a four week period. SUBJECTS: Ten normal subjects with no known autonomic dysfunction were investigated. MAIN OUTCOME MEASURES: These were deep breathing (subject seated and supine), Valsalva manoeuvre, standing up from lying position, and normal relaxed breathing (subject supine). During the tests the electrocardiogram and respiratory pattern were recorded by computer. Beat to beat RR intervals were measured automatically from the electrocardiogram, and from these the results of the tests were calculated. RESULTS: Variance analysis showed significant between subject variability for all tests (p < 0.005), but some tests showed a much smaller relative within subject variability than others. Average repeatability data (within subject SD) for each test were calculated, and included deep breathing sitting (max-min) RR (46 ms), Valsalva ratio (0.17), and lying to standing RR ratio (0.11). These compare with between subject SDs of 65 ms, 0.38, and 0.13 respectively, at mean values of 305 ms, 1.92, and 1.15 respectively. The data highlighted one subject with the poorest repeatability, whose electrocardiogram turned out on closer inspection to be under atrial rather than sinus control at times. Poor repeatability in the other subjects was related to variability in the respiratory pattern, and in the deep breathing test, repeat variability was significantly correlated (r = 0.79) with variability in the respiratory amplitude (p < 0.05). CONCLUSIONS: Repeatability data should be available to each laboratory carrying out autonomic function tests. The data provided in this study could be used as a baseline. Poor repeatability highlights the need to re-examine the test procedures, or the test data from specific subjects. Variability of respiratory pattern is associated with poor repeatability, and so careful instructions on respiration should be given to each subject before the tests.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。