Discovery of low mucus adhesion surfaces

低粘液粘附表面的发现

阅读:1

Abstract

Mucus secretion from the body is ubiquitous, and finding materials that resist mucus adhesion is a major technological challenge. Here, using a high throughput platform with photo-induced graft polymerization, we first rapidly synthesized, screened and tested a library of 55 different surfaces from six functional monomer classes to discover porcine intestinal low mucus adhesion surfaces using a 1h static mucus adsorption protocol. From this preliminary screen, two chemistries, a zwitterionic ([2-(acryloyloxy)ethyl] trimethylammonium chloride) and a multiple hydroxyl (N-[tris(hydroxymethyl)methyl]acrylamide) surface, exhibited significantly low mucus adhesion from a Langmuir-type isotherm when exposed to increasing concentrations of mucus for 24 h. Apolar or hydrophobic interactions were likely the dominant attractive forces during mucus binding since many polar or hydrophilic monomers reduced mucus adhesion. Hansen solubility parameters were used to illustrate the importance of monomer polarity and hydrogen bonding in reducing mucus adsorption. For a series of polyethylene glycol (PEG) monomers with changing molecular weight from 144 g mol⁻¹ to 1100 g mol⁻¹, we observed an excellent linear correlation (R²=0.998) between relative amount adsorbed and the distance from a water point in a specialized Hansen solubility parameter plot, emphasizing the role of surface-water interactions for PEG modified surfaces.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。