Spatial calibration and PM(2.5) mapping of low-cost air quality sensors

低成本空气质量传感器的空间校准和PM(2.5)测绘

阅读:1

Abstract

The data quality of low-cost sensors has received considerable attention and has also led to PM(2.5) warnings. However, the calibration of low-cost sensor measurements in an environment with high relative humidity is critical. This study proposes an efficient calibration and mapping approach based on real-time spatial model. The study carried out spatial calibration, which automatically collected measurements of low-cost sensors and the regulatory stations, and investigated the spatial varying pattern of the calibrated low-cost sensor data. The low-cost PM(2.5) sensors are spatially calibrated based on reference-grade measurements at regulatory stations. Results showed that the proposed spatial regression approach can explain the variability of the biases from the low-cost sensors with an R-square value of 0.94. The spatial calibration and mapping algorithm can improve the bias and decrease to 39% of the RMSE when compared to the nonspatial calibration model. This spatial calibration and real-time mapping approach provide a useful way for local communities and governmental agencies to adjust the consistency of the sensor network for improved air quality monitoring and assessment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。