Feasibility of Deploying Inhaler Sensors to Identify the Impacts of Environmental Triggers and Built Environment Factors on Asthma Short-Acting Bronchodilator Use

利用吸入器传感器识别环境诱因和建筑环境因素对哮喘短效支气管扩张剂使用影响的可行性研究

阅读:1

Abstract

BACKGROUND: Epidemiological asthma research has relied upon self-reported symptoms or healthcare utilization data, and used the residential address as the primary location for exposure. These data sources can be temporally limited, spatially aggregated, subjective, and burdensome for the patient to collect. OBJECTIVES: First, we aimed to test the feasibility of collecting rescue inhaler use data in space-time using electronic sensors. Second, we aimed to evaluate whether these data have the potential to identify environmental triggers and built environment factors associated with rescue inhaler use and to determine whether these findings would be consistent with the existing literature. METHODS: We utilized zero-truncated negative binomial models to identify triggers associated with inhaler use, and implemented three sensitivity analyses to validate our findings. RESULTS: Electronic sensors fitted on metered dose inhalers tracked 5,660 rescue inhaler use events in space and time for 140 participants from 13 June 2012 to 28 February 2014. We found that the inhaler sensors were feasible in passively collecting objective rescue inhaler use data. We identified several environmental triggers with a positive and significant association with inhaler use, including: AQI, PM10, weed pollen, and mold. Conversely, the spatial distribution of tree cover demonstrated a negative and significant association with inhaler use. CONCLUSIONS: Utilizing a sensor to capture the signal of rescue inhaler use in space-time offered a passive and objective signal of asthma activity. This approach enabled detailed analyses to identify environmental triggers and built environment factors that are associated with asthma symptoms beyond the residential address. The application of these new technologies has the potential to improve our surveillance and understanding of asthma. Citation: Su JG, Barrett MA, Henderson K, Humblet O, Smith T, Sublett JW, Nesbitt L, Hogg C, Van Sickle D, Sublett JL. 2017. Feasibility of deploying inhaler sensors to identify the impacts of environmental triggers and built environment factors on asthma short-acting bronchodilator use. Environ Health Perspect 125:254-261; http://dx.doi.org/10.1289/EHP266.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。