Clinical Outcome of Prefabricated Zirconia Crowns Cemented with Self-Adhesive Resin and Pure Glass Ionomer on Primary Teeth: A Retrospective Cohort Study

预制氧化锆冠采用自粘树脂和纯玻璃离子粘接剂在乳牙上的临床效果:一项回顾性队列研究

阅读:1

Abstract

Retentive strength data are critical to predicting the long-term clinical performance of zirconia crowns for primary teeth. Objectives: This research assessed the clinical outcome of prefabricated zirconia crowns (PZCs) cemented with either self-adhesive resin cement or pure glass ionomer cement in the primary teeth of children. Method: In the present research, a sample of 162 prefabricated zirconia crowns were collected through convenience sampling. A follow-up examination was conducted at 12 and 24 months to assess the clinical outcomes of PZCs post cementation. Results: Zirconia crowns cemented with self-adhesive resin showed high clinical outcomes at both 12 and 24 months, with 95.1% of crowns retained. In contrast, crowns cemented with glass ionomer cement had slightly lower clinical outcomes, with 91.4% retained at 12 months and 84.0% retained at 24 months, indicating a significant difference (p-value). Long-term follow-up is crucial for the optimal maintenance of crown stability. Conclusions: Self-adhesive resin cement is a viable option for cementing PZCs in pediatric dentistry, demonstrating satisfactory clinical performance over both 12 and 24 months. Future studies comparing different types of cement are recommended for further validation of these results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。