Diagnostic accuracy of telestroke consultation: a Louisiana based tele-network experience

远程卒中会诊的诊断准确性:路易斯安那州远程医疗网络经验

阅读:1

Abstract

BACKGROUND AND PURPOSE: Telestroke has grown significantly since its implementation. Despite growing utilization, there is a paucity of data regarding the diagnostic accuracy of telestroke to distinguish between stroke and its mimics. We aimed to evaluate diagnostic accuracy of telestroke consultations and explore the characteristics of misdiagnosed patients with a focus on stroke mimics. METHODS: We conducted a retrospective study of all the consultations in our Ochsner Health's TeleStroke program seen between April 2015 and April 2016. Consultations were classified into one of three diagnostic categories: stroke/transient ischemic attack, mimic, and uncertain. Initial telestroke diagnosis was compared with the final diagnosis post review of all emergency department and hospital data. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+) and negative likelihood ratio (LR-) for diagnosis of stroke/TIA versus mimic were calculated. Area under receiver-operating characteristic curve (AUC) analysis to predict true stroke was performed. Bivariate analysis based on the diagnostic categories examined association with sex, age, NIHSS, stroke risk factors, tPA given, bleeding after tPA, symptom onset to last known normal, symptom onset to consult, timing in the day, and consult duration. Logistic regression was performed as indicated by bivariate analysis. RESULTS: Eight hundred and seventy-four telestroke evaluations were included in our analysis. Accurate diagnosis through teleneurological consultation was seen in 85% of which 532 were strokes (true positives) and 170 were mimics (true negatives). Sensitivity, specificity, PPV, NPV were 97.8, 82.5, 93.7 and 93.4%, respectively. LR+ and LR- were 5.6 and 0.03. AUC (95% CI) was 0.9016 (0.8749-0.9283). Stroke mimics were more common with younger age and female gender and in those with less vascular risk factors. LR revealed OR (95% CI) of misdiagnosis for female gender of 1.9 (1.3-2.9). Lower age and lower NIHSS score were other predictors of misdiagnosis. CONCLUSION: We report high diagnostic accuracy of the Ochsner Telestroke Program in discriminating stroke/TIA and stroke mimics, with slight tendency towards over diagnosis of stroke. Female gender, younger age and lower NIHSS score were associated with misdiagnosis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。