Biocompatible Solutions and Long-Term Changes in Peritoneal Solute Transport

生物相容性溶液和腹膜溶质转运的长期变化

阅读:1

Abstract

BACKGROUND AND OBJECTIVES: The inflammation-driven increase in peritoneal solute transport rate that occurs during long-term peritoneal dialysis is associated with higher mortality, hospitalization, and encapsulating peritoneal sclerosis. Because biocompatible solutions were developed to mitigate these effects, we examined the association with their use and longitudinal peritoneal solute transport rate. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We analyzed subjects from the multinational prospective Global Fluid Study with three or more peritoneal solute transport rate measurements >2 months from the start of peritoneal dialysis. Follow-up was for 7.5 years (median, 2.3 years; interquartile range, 1.8-3.6) in biocompatible solutions and 12.8 years (median, 3.2 years; interquartile range, 1.9-4.3) for standard solutions. Using a random intercept/slopes multilevel model, we examined the association of patients using biocompatible solutions and peritoneal solute transport rate over time, adjusting for center effects, dialysate dextrose concentration, baseline dialysate IL-6 concentration, icodextrin use, residual kidney function, and peritonitis. RESULTS: Of 366 patients, the 71 receiving biocompatible solutions throughout their time on peritoneal dialysis had a mean adjusted dialysate-to-plasma creatinine ratio of 0.67 compared with 0.72 for standard solutions (P=0.02). With duration of treatment, there was a continuous increase in peritoneal solute transport rate in patients using standard solutions (range, 2 months to 4 years). In contrast, patients using biocompatible solutions had peritoneal solute transport rates that plateaued after 2 years of therapy. These changes in peritoneal solute transport rate were independent of baseline inflammation and time-varying predictors of faster peritoneal solute transport rate. In patients suffering episodes of peritonitis while using standard solutions, there was an associated increase in peritoneal solute transport rate of 0.020 (95% confidence interval, 0.01 to 0.03) per episode, whereas in patients using biocompatible solutions, there was no change in this parameter (-0.014; 95% confidence interval, -0.03 to <0.01). CONCLUSIONS: These data suggest that a different temporal pattern in changes in peritoneal solute transport rate occurs during the course of peritoneal dialysis according to solution type and that patients using biocompatible solutions may avoid the increase in solute transport associated with peritonitis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。