Associations between Hemodialysis Facility Practices to Manage Fluid Volume and Intradialytic Hypotension and Patient Outcomes

血液透析中心液体容量管理措施与透析中低血压及患者预后之间的关联

阅读:1

Abstract

BACKGROUND AND OBJECTIVES: Fluid overload and intradialytic hypotension are associated with cardiovascular events and mortality in patients on hemodialysis. We investigated associations between hemodialysis facility practices related to fluid volume and intradialytic hypotension and patient outcomes. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Data were analyzed from 10,250 patients in 273 facilities across 12 countries, from phase 4 of the Dialysis Outcomes and Practice Patterns Study (DOPPS; 2009-2012). Cox regression models (shared frailty) were used to estimate associations between facility practices reported by medical directors in response to the DOPPS Medical Directors Survey and all-cause and cardiovascular mortality and hospitalization, and cardiovascular events, adjusting for country, age, sex, dialysis vintage, predialysis systolic BP, cardiovascular comorbidities, diabetes, body mass index, smoking, residual kidney function, dialysis adequacy, and vascular access type. RESULTS: Of ten facility practices tested (chosen a priori), having a protocol that specifies how often to assess dry weight in most patients was associated with lower all-cause (hazard ratio [HR], 0.78; 99% confidence interval [99% CI], 0.64 to 0.94) and cardiovascular mortality (HR, 0.72; 99% CI, 0.55 to 0.95). Routine orthostatic BP measurement to assess dry weight was associated with lower all-cause hospitalization (HR, 0.86; 99% CI, 0.77 to 0.97) and cardiovascular events (HR, 0.85; 99% CI, 0.73 to 0.98). Routine use of lower dialysate temperature to limit or prevent intradialytic hypotension was associated with lower cardiovascular mortality (HR, 0.76; 99% CI, 0.58 to 0.98). Routine use of an online volume indicator to assess dry weight was associated with higher all-cause hospitalization (HR, 1.19; 99% CI, 1.02 to 1.38). Routine use of sodium modeling/profiling to limit or prevent intradialytic hypotension was associated with higher all-cause mortality (HR, 1.36; 99% CI, 1.14 to 1.63), cardiovascular mortality (HR, 1.34; 99% CI, 1.04 to 1.73), and cardiovascular events (HR, 1.21; 99% CI, 1.03 to 1.43). CONCLUSIONS: Hemodialysis facility practices relating to the management of fluid volume and intradialytic hypotension are associated with patient outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。