Automated Determination of Left Ventricular Function Using Electrocardiogram Data in Patients on Maintenance Hemodialysis

利用心电图数据自动测定维持性血液透析患者左心室功能

阅读:2

Abstract

BACKGROUND AND OBJECTIVES: Left ventricular ejection fraction is disrupted in patients on maintenance hemodialysis and can be estimated using deep learning models on electrocardiograms. Smaller sample sizes within this population may be mitigated using transfer learning. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We identified patients on hemodialysis with transthoracic echocardiograms within 7 days of electrocardiogram using diagnostic/procedure codes. We developed four models: (1) trained from scratch in patients on hemodialysis, (2) pretrained on a publicly available set of natural images (ImageNet), (3) pretrained on all patients not on hemodialysis, and (4) pretrained on patients not on hemodialysis and fine-tuned on patients on hemodialysis. We assessed the ability of the models to classify left ventricular ejection fraction into clinically relevant categories of ≤40%, 41% to ≤50%, and >50%. We compared performance by area under the receiver operating characteristic curve. RESULTS: We extracted 705,075 electrocardiogram:echocardiogram pairs for 158,840 patients not on hemodialysis used for development of models 3 and 4 and n=18,626 electrocardiogram:echocardiogram pairs for 2168 patients on hemodialysis for models 1, 2, and 4. The transfer learning model achieved area under the receiver operating characteristic curves of 0.86, 0.63, and 0.83 in predicting left ventricular ejection fraction categories of ≤40% (n=461), 41%-50% (n=398), and >50% (n=1309), respectively. For the same tasks, model 1 achieved area under the receiver operating characteristic curves of 0.74, 0.55, and 0.71, respectively; model 2 achieved area under the receiver operating characteristic curves of 0.71, 0.55, and 0.69, respectively, and model 3 achieved area under the receiver operating characteristic curves of 0.80, 0.51, and 0.77, respectively. We found that predictions of left ventricular ejection fraction by the transfer learning model were associated with mortality in a Cox regression with an adjusted hazard ratio of 1.29 (95% confidence interval, 1.04 to 1.59). CONCLUSION: A deep learning model can determine left ventricular ejection fraction for patients on hemodialysis following pretraining on electrocardiograms of patients not on hemodialysis. Predictions of low ejection fraction from this model were associated with mortality over a 5-year follow-up period. PODCAST: This article contains a podcast at https://www.asn-online.org/media/podcast/CJASN/2022_06_06_CJN16481221.mp3.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。