Development and validation of a microwave-assisted digestion technique as a rapid sample preparation method for the estimation of selenium in pharmaceutical dosage forms by ICP-OES

开发并验证了一种微波辅助消解技术,作为一种快速样品前处理方法,用于通过电感耦合等离子体发射光谱法(ICP-OES)测定药物制剂中的硒含量。

阅读:1

Abstract

Selenium is a class 2B element according to the International Council for Harmonization Q3D guidelines. Selenium sulfide is an anti-infective agent with antifungal and antibacterial properties used to treat dandruff and seborrheic dermatitis. The literature survey revealed that most of the analytical techniques to estimate selenium were time-consuming and/or required high skill levels. The process involved identifying the isotopes, selecting the measurement approach, and optimizing a typical microwave-aided digesting procedure. Ammonium hydrogen difluoride, water, and concentrated nitric acid were added to the samples. The confirmed microwave digestion program was a two-step program where in the initial step, the samples were ramped at 200°C for 20 min and held for 5 min. Later, samples were cooled and neutralized by boric acid, then ramped for 20 min to a temperature of 180°C and held for 10 min. Selenium was estimated at 196.090 nm by inductively coupled plasma optical emission spectroscopy (ICP-OES). System suitability was run before initiating analysis to ensure that system performance was consistent. Analytical validation parameters, such as the specificity of the method, were demonstrated at 196.090 nm, linearity was proven from 10 ppm to 150 ppm of selenium concentration, the detection limit was 1.28 ppm, and the limit of quantification was 3.89 ppm. Robustness was confirmed for small changes to ICP-OES operating conditions. The precision of the method demonstrated by analyzing the percentage relative standard deviation for six injections was found to be less than 2.0%. Accuracy was confirmed from 10 ppm to 150 ppm, and all the samples were observed to be within the range of 95%-105%. A common microwave-assisted digestion technique was developed and validated as well. The precision, specificity, linearity, accuracy, and robustness of the method for estimating selenium in selenium sulfide drug substances and various pharmaceutical dosage forms were demonstrated. This newly developed microwave-assisted digestion technique has optimum sensitivity and is highly reproducible and time-saving than the existing methods This method can be applied to numerous matrices for a finished dosage of selenium sulfide formulations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。