[Evaluation of the accuracy of three-dimensional data acquisition from liquid- interference surfaces assisted by a scanner head with a compressed airflow system]

[利用压缩气流扫描头辅助采集液体干涉表面三维数据精度的评估]

阅读:1

Abstract

OBJECTIVE: To quantitatively evaluate the accuracy of data obtained from liquid-interference surfaces using an intraoral 3D scanner (IOS) integrated with a compressed airflow system, so as to provide clinical proof of accuracy for the application of the compressed airflow system-based scanning head in improving data quality on liquid-interference surfaces. METHODS: The study selected a standard model as the scanning object, adhering to the "YY/T 1818-2022 Dental Science Intraoral Digital Impression Scanner" guidelines, a standard that defined parameters for intraoral scanning. To establish a baseline for accuracy, the ATOS Q 12M scanner, known for its high precision, was used to generate true reference values. These true values served as the benchmark for evaluating the IOS performance. Building on the design of an existing scanner, a new scanning head was developed to integrate with a compressed airflow system. This new design aimed to help the IOS capture high-precision data on surfaces where liquid-interference, such as saliva, might otherwise degrade scanning accuracy. The traditional scanning method, without airflow assistance, was employed as a control group for comparison. The study included five groups in total, one control group and four experimental groups, to investigate the effects of scanning lens obstruction, airflow presence, liquid media, and the use of the new scanning head on scanning process and accuracy. Each group underwent 15 scans, generating ample data for a robust statistical comparison. By evaluating trueness and precision in each group, the study assessed the impact of the compressed airflow system on the accuracy of IOS data collected from liquid-interference surfaces. Additionally, we selected Elite and Primescan scanners as references for numerical accuracy values. RESULTS: The scanning accuracy on liquid-interference surfaces was significantly reduced in terms of both trueness and precision [Trueness: 18.5 (6.5) vs. 38.0 (6.7), P < 0.05; Precision: 19.1 (8.5) vs. 31.7 (15.0), P < 0.05]. The use of the new scanning head assisted by the compressed airflow system significantly improved the scanning accuracy [Trueness: 22.3(7.6) vs. 38.0 (6.7), P < 0.05; Precision: 25.8 (9.6) vs. 31.7 (15.0), P < 0.05]. CONCLUSION: The scanning head based on the compressed airflow system can assist in improving the accuracy of data obtained from liquid-interference surfaces by the IOS.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。