A Suggested Equivalent Method for a Drainage Structure to Analyze Seepage in Tailings Dam

一种用于分析尾矿坝渗流的排水结构等效方法建议

阅读:1

Abstract

To better understand the seepage field in tailings dam with a drainage structure that combines drainage mat, drainage tube, and geotextile, an equivalent seepage analysis method for the drainage structure is presented. In the method, an equivalent drainage structure is suggested to replace the original drainage. It has enough size to be easily presented in the three-dimensional (3d) model of a tailings dam. According to a back analysis procedure using the quasi-3d models of a tailings dam with original and equivalent drainage structures, the material properties of the equivalent drainage structure can be obtained under the principle of drainage capacity equivalence. It is demonstrated that the suggested method is accurate enough to capture the seepage field in a tailings dam based on comparing the calculated and measured phreatic lines in a tailings dam for verification. Then, the method is employed to investigate the seepage field in a tailings dam in China for a case study. The rise of water level, damage of drainage structure, or increase of tailings discharge speed and time will lift up phreatic line. After terminating tailings discharge, phreatic line will first rise and then fall. The effect of tailings discharge on phreatic line will almost disappear after terminating tailings discharge for 24 h.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。