Use of CPR feedback devices in resuscitation training: A systematic review and meta-analysis of randomized controlled trials

在复苏培训中使用心肺复苏反馈装置:随机对照试验的系统评价和荟萃分析

阅读:1

Abstract

OBJECTIVES: The use of cardiopulmonary resuscitation (CPR) feedback devices during training is increasing. This review evaluates whether incorporating CPR feedback devices in training improves patient survival, CPR quality in actual resuscitation, skill acquisition and retention after training. METHODS: This systematic review was part of the continuous evidence evaluation process of the International Liaison Committee on Resuscitation (ILCOR). We searched MEDLINE, EMBASE, and SCOPUS databases from inception to September 30, 2024, including randomized controlled trials (RCTs) in all languages (with an English abstract) comparing CPR training with and without feedback devices. Outcome included patient survival, quality of clinical performance in resuscitation, and CPR skill acquisition and retention. Non-RCT studies, unpublished work without peer review or animal studies were excluded. Risk of bias was assessed using Cochrane tools, and certainty of evidence was graded using the Grading of Recommendations Assessment, development and Evaluation (GRADE) approach. Standardized mean difference (SMD) were calculated and pooled effects were analyzed using random-effects models. PROSPERO CRD42023488130. RESULTS: We identified 20 RCTs with 4579 participants. Risks of bias ranged from low to critical (low: 8, moderate: 9, and critical: 3). No studies evaluated the patient survival, clinical performance in resuscitation or cost-effectiveness. Compared to no feedback, using CPR feedback devices during training significantly improved key quality metrics. Pooled effect sizes were 0.76 (95%CI 0.02 - 1.50) for mean compression depth (15 studies), 0.98 (95%CI: 0.10 - 1.87) for depth compliance (16 studies), 0.29 (95%CI: 0.10 - 0.48) for mean rate (17 studies), 0.44 (95%CI: 0.23 - 0.66) for rate compliance (9 studies), and 0.53 (95%CI: 0.31 - 0.75) for recoil compliance (10 studies) in favour of using feedback devices during training. Heterogeneity was large (I(2) > 50%) in all analyses. Planned subgroup analyses revealed no statistically significant interaction between healthcare professionals and laypersons. Using the GRADE approach, the certainty of evidence was downgraded for certain outcomes due to critical risk of bias for 3 studies and inconsistency but upgraded for strong association. CONCLUSION: The use of CPR feedback devices during resuscitation training improves key quality metrics of CPR performance, with moderate to high certainty of evidence. However, further studies are needed to evaluate the impact on cost-effectiveness, clinical performance and patient outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。