Abstract
BACKGROUND: A respiratory function monitor (RFM) provides real-time positive pressure ventilation feedback. Whether providers use RFM during neonatal resuscitation is unknown. METHODS: Ancillary study to the MONITOR(NCT03256578) randomised controlled trial. Neonatal resuscitation leaders at two centres wore eye-tracking glasses, and visual attention (VA) patterns were compared between RFM-visible and RFM-masked groups. RESULTS: 14 resuscitations (6 RFM-visible, 8 RFM-masked) were analysed. The median total gaze duration on the RFM was significantly higher with a visible RFM (29% vs 1%, p<0.01), while median total gaze duration on other physical objects was significantly lower with a visible RFM (3% vs 8%, p=0.02). Median total gaze duration on the infant was lower with RFM visible, although not statistically significantly (29% vs 46%, p=0.05). CONCLUSION: Providers' VA patterns differed during neonatal resuscitation when the RFM was visible, emphasising the importance of studying the impact of additional delivery room technology on providers' behaviour.