Case Report: Left Ventricular Unloading Using a Mechanical CPR Device in a Prolonged Accidental Hypothermic Cardiac Arrest Treated by VA-ECMO - a Novel Approach

病例报告:采用机械式心肺复苏装置进行左心室卸载治疗持续性意外低温心脏骤停并接受体外膜肺氧合(VA-ECMO)治疗的新方法

阅读:1

Abstract

We recently treated a 36-year-old previously healthy male with a prolonged hypothermic (lowest temperature 22.3°C) cardiac arrest after an alcohol intoxication with a return of spontaneous circulation after 230min of mechanical cardiopulmonary resuscitation and rewarming by veno-arterial ECMO with femoral cannulation and retrograde perfusion of the aortic arch. Despite functional veno-arterial ECMO, we continued mechanical cardiopulmonary resuscitation (Auto Pulse™ device, ZOLL Medical Corporation, Chelmsford, USA) until return of spontaneous circulation to prevent left ventricular distention from persistent ventricular fibrillation. The case was further complicated by extensive trauma caused by mechanical cardiopulmonary resuscitation (multiple rib fractures, significant hemothorax, and a liver laceration requiring massive transfusion), lung failure necessitating a secondary switch to veno-venous ECMO, and acute kidney injury with the need for renal replacement therapy. Shortly after return of spontaneous circulation, the patient was already following commands and could be discharged 3 weeks later without neurologic, cardiac, or renal sequelae and being entirely well. Prolonged accidental hypothermic cardiac arrest might present with excellent outcomes when supported with veno-arterial ECMO. Until return of spontaneous circulation, one might consider continuing with mechanical cardiopulmonary resuscitation in addition to ECMO to allow some left ventricular unloading. However, the clinician should keep in mind that prolonged mechanical cardiopulmonary resuscitation may cause severe injuries.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。