Abstract

AIM OF THE STUDY: Current guidelines advise rescuers to initiate cardiopulmonary resuscitation if a child is unresponsive, not breathing normally, and shows no signs of life. Manual pulse checks are considered unreliable and time-consuming. This systematic review evaluates the accuracy and duration of recommended pulse check methods during pediatric cardiac arrest and explores emerging diagnostic techniques. METHODS: For this systematic review (PROSPERO ID CRD42024549535) three databases (PubMed, Embase, and Cochrane) were searched for articles published on this topic. An initial search was conducted on April 24, 2024, with an updated search using the same search strategy on February 16, 2025. Two authors independently screened the articles. One author extracted the data while a second author double-checked it. Quality and certainty of the evidence were evaluated using the QUADAS-2 and GRADE tools evaluated the evidence's quality and certainty. Studies were included if they compared manual pulse checks against alternative pulse check sites or other methods in pediatric patients. The data is presented descriptively. RESULTS: A total of three studies were included. These studies involved 39 pediatric patients and a total of 376 pulse checks. Out of the 47 infants and children included, only 14 were in cardiac arrest. The remaining 33 patients were on mechanical circulatory support with either VA-ECMO or LVAD. In total, 183 nurses and 181 physicians performed 376 pulse or ultrasound checks. Due to their specialty, 122 nurses and 89 doctors were classified as experienced. Sensitivity and specificity of manual pulse check ranged from 76 to 100% and 64-79%, respectively. When experienced providers conducted pulse checks, sensitivity and specificity were higher (76-100% and 62-82%, respectively) compared to inexperienced providers (67-82% and 44-95%).The mean duration of pulse checks was 20 s, with an accuracy of 85%. CONCLUSION: Despite high heterogeneity among included studies, manual pulse checks only achieved moderate accuracy with a prolonged duration. This suggests that manual pulse checks are unreliable in children for determination cardiac arrest state and need for ongoing CPR.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。