The impact of introducing real time feedback on ventilation rate and tidal volume by ambulance clinicians in the North East in cardiac arrest simulations

在英国东北部的心脏骤停模拟训练中,救护车临床医生引入实时反馈通气频率和潮气量的影响

阅读:1

Abstract

BACKGROUND: Research suggests rescuers deliver ventilations outside of recommendations during out of hospital cardiac arrest (OHCA), which can be deleterious to survival. We aimed to determine if ambulance clinician compliance with ventilation recommendations could be improved using the Zoll Accuvent real time ventilation feedback device (VFD). METHODS: Participants simulated a two-minute cardiac arrest scenario using a mannequin and defibrillator without ventilation feedback. Eligible for inclusion were all clinicians aged ≥18 years who perform cardiopulmonary resuscitation (CPR) as part of their role, who had completed an internal advanced life support (ALS) refresher. Following familiarisation of a few minutes with the VFD, participants repeated the two-minute scenario with ventilation feedback. Ventilation rate and volume and CPR quality were recorded. Primary outcome was % difference in ventilation compliance with and without feedback. Secondary outcomes were differences between paramedic and non-paramedic clinicians and compliance with chest compression guidelines. RESULTS: One hundred and six participants completed the study. Median ventilation rate without feedback was 10 (IQR 8-14, range 4-30) compared to 9 (IQR 9-9, range 6-17) with feedback; median tidal volume without feedback was 630 mls (IQR 518-725, range 201-1114) compared to 546 mls (IQR 531-560, range 490-750) with feedback. Proportion of clinicians ≥50% compliant with European Resuscitation Council ventilation recommendations were significantly greater with ventilation feedback compared to without, 91% vs. 9%, (McNemars test p = <0.0001). Paramedics out performed non-paramedic clinicians with and without feedback and compression quality was not compromised by using the VFD. CONCLUSIONS: Ambulance clinician baseline ventilation quality was frequently outside of recommendations, but a VFD can ensure treatment is within evidence-based recommendations. Further research is required to validate the use of the VFD in true clinical practice and to evaluate the relationship between improved ventilation quality during OHCA and patient outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。