Automated specific capture of hepatitis C virus RNA with probes and paramagnetic particle separation

利用探针和顺磁性颗粒分离技术自动特异性捕获丙型肝炎病毒RNA

阅读:1

Abstract

We developed and evaluated a prototype automated specimen preparation instrument for the specific capture of hepatitis C virus (HCV) RNA with probes and magnetic bead-fluid separation. HCV RNA was isolated from serum by lysis of virus particles with a chaotropic agent, followed by hybridization of the RNA with biotinylated probes and capture of the hybridized RNA with streptavidin-coated paramagnetic particles. After washing of the hybrid-particle complexes to remove nonspecifically bound materials, the particles were resuspended in a specimen diluent and were then ready for amplification and detection with a fully automated PCR system (COBAS AMPLICOR; Roche Diagnostic Systems). The analytical sensitivity in the dilution series was 33 copies per ml or greater. Comparison of the test results with those obtained by a manual method based on organic extraction and precipitation of RNA (SepaGene RV-R; Sanko Junyaku Co., Ltd.) showed 93% (49 of 53 samples) sensitivity and 100% (12 of 12 samples) specificity. There was 94% overall agreement between results. When RNA was extracted by the manual method from serum containing 10(3) or 10(5) copies of HCV per ml in the presence of heparin, there was an inhibitory effect on detection of both HCV RNA and the internal control. In contrast, when RNA was extracted from the serum by the automated method, there was no inhibitory effect. This inhibitory effect of heparin on the manual method was also observed for a series of serum specimens from a hemodialysis patient, but the inhibitory effect was eliminated by the automated specimen preparation method. In summary, a fully automated RNA extraction system for PCR detection of HCV RNA by use of specific capture with probes and magnetic bead-fluid separation was shown to have performance similar to that of the conventional manual method. In addition, it successfully eliminated the inhibitory effect of the heparin in the serum and permitted the detection of HCV RNA in serum samples from a hemodialysis patient. The prototype automated RNA extraction system is suitable as a totally automated system, starting with RNA extraction to detection of HCV, if it was combined with the fully automated COBAS AMPLICOR PCR system.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。