P-99. Comparative Analysis of False Positive Results in Low and High Risk U.S. Populations: New Access HIV Ag/Ab combo Assay vs. Abbott ARCHITECT HIV Ag/Ab Combo Assay

P-99. 美国低风险和高风险人群假阳性结果的比较分析:新Access HIV抗原/抗体组合检测与雅培ARCHITECT HIV抗原/抗体组合检测

阅读:2

Abstract

BACKGROUND: The fully automated 4(th) gen HIV Ag/Ab combo assay by Beckman Coulter, Inc. on the DxI 9000 Access Immunoassay analyzer allows for separate reporting of HIV-1 p24 Ag and HIV-1/HIV-2 Ab results, with a time to first result of ~30 minutes and a sample volume of 60µL. To evaluate its performance, a U.S. multisite study was conducted to compare the Access HIV Ag/Ab combo assay with the ARCHITECT HIV Ag/Ab Combo assay. False positive rates were assessed in low and high risk U.S. populations with unknown HIV status by comparing the new Access HIV Ag/Ab combo assay with the ARCHITECT HIV Ag/Ab Combo assay.1 Footnotes [Figure: see text] METHODS: The evaluation tested 6,981 low risk and 799 high risk samples (adult, pregnant, pediatric) at 3 clinical trial sites. Following the CDC recommended algorithm, samples that initially tested reactive were subjected to duplicate testing, if repeatedly reactive, were further confirmed using the HIV 1/2 differentiation assay (Geenius HIV-1/2 Supplemental Assay, Bio-Rad), and the HIV-1 RNA PCR Assay (Aptima HIV-1 Quantitative Dx Assay, Hologic, Inc).2 RESULTS: The Access HIV Ag/Ab combo assay showed a lower incidence of false positive results (n=25) in the low risk group with a specificity of 99.6% (n=6981; 95% CI: 99.5-99.8%) compared to the ARCHITECT HIV Ag/Ab Combo assay (n=87) with a specificity of 98.8% (n=6981; 95% CI: 98.5-99.0%). Similarly, in the high risk group, the Access HIV Ag/Ab combo assay yielded fewer false positive results (n=1) with a specificity of 99.9% (n=799; 95% CI: 99.3-100.0%) than the ARCHITECT HIV Ag/Ab Combo assay (n=11) with a specificity of 98.6% (n=799; 95% CI: 97.6-99.2%). CONCLUSION: Falsely reactive HIV test results can have significant consequences for patients and healthcare providers. Selecting an appropriate HIV assay with high sensitivity and specificity is essential. This study provides evidence that the Access HIV Ag/Ab combo assay is an attractive alternative to the ARCHITECT HIV Ag/Ab Combo assay with fewer false positive results, suggesting improved accuracy in identifying HIV infections in both low and high risk U.S. populations. DISCLOSURES: Fred S. Apple, PhD, Mindray: Advisor/Consultant|Werfen: Advisor/Consultant Robert H. Christenson, PhD, DABCC, FADLM, FACC, Beckman Coulter: Advisor/Consultant|Beckman Coulter: Grant/Research Support|Beckman Coulter: Honoraria|Becton Dickinson: Advisor/Consultant|Becton Dickinson: Grant/Research Support|Becton Dickinson: Honoraria|QuidelOrtho: Advisor/Consultant|QuidelOrtho: Grant/Research Support|QuidelOrtho: Honoraria|Roche Diagnostics: Advisor/Consultant|Roche Diagnostics: Board Member|Roche Diagnostics: Grant/Research Support|Roche Diagnostics: Honoraria|Siemens Healthineers: Advisor/Consultant|Siemens Healthineers: Board Member|Siemens Healthineers: Grant/Research Support|Siemens Healthineers: Honoraria

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。