Feasibility and basic acoustic characteristics of intelligent long-term bowel sound analysis in term neonates

足月新生儿智能长期肠鸣音分析的可行性及基本声学特征

阅读:1

Abstract

OBJECTIVE: Bowel dysfunction continues to be a serious issue in neonates. Traditional auscultation of bowel sounds as a diagnostic tool in neonatal gastrointestinal problems is limited by skill and inability to document and reassess. Consequently, in order to objectively and noninvasively examine the viability of continuous assessment of bowel sounds, we utilized an acoustic recording and analysis system to capture bowel sounds and extract acoustic features in term neonates. METHODS: From May 1, 2020 to September 30, 2020, 82 neonates who were hospitalized because of hyperbilirubinemia were included. For 20 h, a convolutional neural network-based acoustic recorder that offers real-time, wireless, continuous auscultation was employed to track the bowel sounds of these neonates. RESULTS: (1) Usable data on five acoustic parameters of bowel sound was recorded for 68 neonates, and the median values were as follows: The rate was 25.80 times/min [interquartile range (IQR): 15.63-36.20]; the duration was 8.00 s/min (IQR: 4.2-13.20); the amplitude was 0.46 (IQR: 0.27-0.68); the frequency was 944.05 Hz (IQR: 848.78-1,034.90); and the interval time was 2.12 s (IQR: 1.3-3.5). (2) In comparison to the parameters of the bowel sounds recorded from the right lower abdomen in 68 infants, the acoustic parameters of the 10 out of 68 infants from chest controls and blank controls were considerably different. (3) The 50%-75% breast milk intake group had the highest rate, the longest duration, and the highest amplitude of bowel sounds, while the >75% breast milk intake group had the highest frequency of bowel sounds. (4) Compared with neonates without hyperbilirubinemia, there was no significant difference in the five parameters of bowel sounds in hyperbilirubinemia infants; nor was there a significant effect of phototherapy and non-phototherapy status on the parameters of bowel sounds during bowel sound monitoring in hyperbilirubinemia patients. (5) A mild transient skin rash appeared on the skin of three infants. No other adverse events occurred. CONCLUSION: The acoustic recording and analysis system appears useful for monitoring bowel sounds using a continuous, invasive, and real-time approach. Neonatal bowel sounds are affected by various feeding types rather than hyperbilirubinemia and phototherapy. Potential influencing factors and the significance of their application in neonatal intestinal-related disorders require further research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。