EEG Monitoring Technique Influences the Management of Hypoxic-Ischemic Seizures in Neonates Undergoing Therapeutic Hypothermia

脑电图监测技术影响接受治疗性低温疗法的新生儿缺氧缺血性癫痫的管理

阅读:1

Abstract

Electroencephalogram (EEG) monitoring techniques for neonatal hypoxia-ischemia (HI) are evolving over time, and the specific type of EEG utilized could influence seizure diagnosis and management. We examined whether the type of EEG performed affected seizure treatment decisions (e.g., the choice and number of antiseizure drugs [ASDs]) in therapeutic hypothermia-treated neonates with HI from 2007 to 2015 in the Johns Hopkins Hospital Neonatal Intensive Care Unit. During this period, 3 different EEG monitoring protocols were utilized: Period 1 (2007-2009), single, brief conventional EEG (1 h duration) at a variable time during therapeutic hypothermia treatment, i.e., ordered when a seizure was suspected; Period 2 (2009-2013), single, brief conventional EEG followed by amplitude-integrated EEG for the duration of therapeutic hypothermia treatment and another brief conventional EEG after rewarming; and Period 3 (2014-2015), continuous video-EEG (cEEG) for the duration of therapeutic hypothermia treatment (72 h) plus for an additional 12 h during and after rewarming. One hundred and sixty-two newborns were included in this retrospective cohort study. As a function of the type and duration of EEG monitoring, we assessed the risk (likelihood) of receiving no ASD, at least 1 ASD, or ≥2 ASDs. We found that the risk of a neonate being prescribed an ASD was 46% less during Period 3 (cEEG) than during Period 1 (brief conventional EEG only) (95% CI 6-69%, p = 0.03). After adjusting for initial EEG and MRI results, compared with Period 1, there was a 38% lower risk of receiving an ASD during Period 2 (95% CI: 9-58%, p = 0.02) and a 67% lower risk during Period 3 (95% CI: 23-86%, p = 0.01). The risk ratio of receiving ≥2 ASDs was not significantly different across the 3 periods. In conclusion, in addition to the higher sensitivity and specificity of continuous video-EEG monitoring, fewer infants are prescribed an ASD when undergoing continuous forms of EEG monitoring (aEEG or cEEG) than those receiving conventional EEG. We recommend that use of continuous video-EEG be considered whenever possible, both to treat seizures more specifically and to avoid overtreatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。