Abstract
With increasing cesarean delivery rates, placenta accreta spectrum (PAS) disorders are occurring more frequently and represent a significant cause of peripartum hemorrhage. Different modalities have been explored to control blood loss during cesarean hysterectomies for PAS disorders, including administration of tranexamic acid (TXA) and balloon occlusion strategies. We present a case of a cesarean hysterectomy for a placenta percreta with the use of TXA and arterial balloon occlusion complicated by a lower extremity arterial thrombus requiring emergent thrombectomy. The outcome of this case suggests using caution with concomitant use of TXA and arterial balloon occlusion.