3D R2* mapping of the placenta during early gestation using free-breathing multiecho stack-of-radial MRI at 3T

利用3T磁共振成像仪,采用自由呼吸多回波径向序列堆叠技术,对妊娠早期胎盘进行三维R2*映射。

阅读:1

Abstract

BACKGROUND: Multiecho gradient-echo Cartesian MRI characterizes placental oxygenation by quantifying R2* . Previous research was performed at 1.5T using breath-held 2D imaging during later gestational age (GA). PURPOSE: To evaluate the accuracy and repeatability of a free-breathing (FB) 3D multiecho gradient-echo stack-of-radial technique (radial) for placental R2* mapping at 3T and report placental R2* during early GA. STUDY TYPE: Prospective. POPULATION: Thirty subjects with normal pregnancies and three subjects with ischemic placental disease (IPD) were scanned twice: between 14-18 and 19-23 weeks GA. FIELD STRENGTH: 3T. SEQUENCE: FB radial. ASSESSMENT: Linear correlation (concordance coefficient, ρ(c) ) and Bland-Altman analyses (mean difference, MD) were performed to evaluate radial R2* mapping accuracy compared to Cartesian in a phantom. Radial R2* mapping repeatability was characterized using the coefficient of repeatability (CR) between back-to-back scans. The mean and spatial coefficient of variation (CV) of R2* was determined for all subjects, and separately for anterior and posterior placentas, at each GA range. STATISTICAL TESTS: ρ(c) was tested for significance. Differences in mean R2* and CV were tested using Wilcoxon Signed-Rank and Rank-Sum tests. P < 0.05 was considered significant. Z-scores for the IPD subjects were determined. RESULTS: FB radial demonstrated accurate (ρ(c) ≥0.996; P < 0.001; |MD|<0.2s(-1) ) and repeatable (CR<4s(-1) ) R2* mapping in a phantom, and repeatable (CR≤4.6s(-1) ) R2* mapping in normal subjects. At 3T, placental R2* mean ± standard deviation was 12.9s(-1) ± 2.7s(-1) for 14-18 and 13.2s(-1)  ± 1.9s(-1) for 19-23 weeks GA. The CV was significantly greater (P = 0.043) at 14-18 (0.63 ± 0.12) than 19-23 (0.58 ± 0.13) weeks GA. At 19-23 weeks, the CV was significantly lower (P < 0.001) for anterior (0.49 ± 0.08) than posterior (0.67 ± 0.11) placentas. One IPD subject had a lower mean R2* than normal subjects at both GA ranges (Z<-2). DATA CONCLUSION: FB radial provides accurate and repeatable 3D R2* mapping for the entire placenta at 3T during early GA. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:291-303.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。