Evaluation of a motion-robust 2D chemical shift-encoded technique for R2* and field map quantification in ferumoxytol-enhanced MRI of the placenta in pregnant rhesus macaques

评估一种运动鲁棒性二维化学位移编码技术在妊娠恒河猴胎盘铁氧乙醇增强磁共振成像中R2*和场图定量分析中的应用

阅读:1

Abstract

BACKGROUND: 3D chemical shift-encoded (CSE)-MRI techniques enable assessment of ferumoxytol concentration but are unreliable in the presence of motion. PURPOSE: To evaluate a motion-robust 2D-sequential CSE-MRI for R2* and B0 mapping in ferumoxytol-enhanced MRI of the placenta. STUDY TYPE: Prospective. ANIMAL MODEL: Pregnant rhesus macaques. FIELD STRENGTH/SEQUENCE: 3.0T/CSE-MRI. ASSESSMENT: 2D-sequential CSE-MRI was compared with 3D respiratory-gated CSE-MRI in placental imaging of 11 anesthetized animals at multiple timepoints before and after ferumoxytol administration, and in ferumoxytol phantoms (0 μg/mL-440 μg/mL). Motion artifacts of CSE-MRI in 10 pregnant women without ferumoxytol administration were assessed retrospectively by three blinded readers (4-point Likert scale). The repeatability of CSE-MRI in seven pregnant women was also prospectively studied. STATISTICAL TESTS: Placental R2* and boundary B0 field measurements (ΔB0) were compared between 2D-sequential and 3D respiratory-gated CSE-MRI using linear regression and Bland-Altman analysis. RESULTS: In phantoms, a slope of 0.94 (r(2) = 0.99, concordance correlation coefficient ρ = 0.99), and bias of -4.8 s(-1) (limit of agreement [LOA], -41.4 s(-1) , +31.8 s(-1) ) in R2*, and a slope of 1.07 (r(2) = 1.00, ρ = 0.99) and bias of 11.4 Hz (LOA -12.0 Hz, +34.8 Hz) in ΔB0 were obtained in 2D CSE-MRI compared with 3D CSE-MRI for reference R2* ≤390 s(-1) . In animals, a slope of 0.92 (r(2) = 0.97, ρ = 0.98) and bias of -2.2 s(-1) (LOA -55.6 s(-1) , +51.3 s(-1) ) in R2*, and a slope of 1.05 (r(2) = 0.95, ρ = 0.97) and bias of 0.4 Hz (LOA -9.0 Hz, +9.7 Hz) in ΔB0 were obtained. In humans, motion-impaired R2* maps in 3D CSE-MRI (Reader 1: 1.8 ± 0.6, Reader 2: 1.3 ± 0.7, Reader 3: 1.9 ± 0.6), while 2D CSE-MRI was motion-free (Reader 1: 2.9 ± 0.3, Reader 2: 3.0 ± 0, Reader 3: 3.0 ± 0). A mean difference of 0.66 s(-1) and coefficient of repeatability of 9.48 s(-1) for placental R2* were observed in the repeated 2D CSE-MRI. DATA CONCLUSION: 2D-sequential CSE-MRI provides accurate R2* and B0 measurements in ferumoxytol-enhanced placental MRI of animals in the presence of respiratory motion, and motion-robustness in human placental imaging. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:580-592.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。